INSTALLATION AND OPERATING INSTRUCTIONS
KBPI SERIES
SCR INDEXING & CYCLING CONTROLS
— Designed for Indexing Applications —
FOR PM DC MOTORS RATED
(1/6 – 1 HP @ 90VDC) and (1/3 – 2 HP @ 180VDC)
TM
TM
This Manual Covers the Following Models
Model No. Operation Part No.
KBPI-240D
KBPI-240DR
Unidirectional
Reversible
8500
8501
See Safety Warning on Page 2
The information contained in this manual is intended to be accurate. However, the manufacturer
retains the right to make changes in design which may not be included herein.
A COMPLETE LINE OF MOTOR DRIVES
Przeglądanie stron 0
1 2 3 4 5 6 ... 23 24

Podsumowanie treści

Strona 1 - KBPI SERIES

See Page 2This control willnot operatewithout installingthe correctarmature fuse –suppliedseparately.© 1998 KB Electronics, Inc.INSTALLATION AND OPERA

Strona 2

8 INCHES [mm]FIG. 3 – MECHANICAL SPECIFICATIONSTMTM

Strona 3

9III. SETTING AC LINE AND MOTOR VOLTAGE.The KBPI is factory set to operate with a 230VAC - 50/60 Hz AC line input and a 180-VDC PMmotor. By utilizing

Strona 4

10FIG. 4 – AC LINE AND MOTORCONNECTION DIAGRAMV. WIRINGWARNING! Read Safety Warning on page 2 before attempting to use this control.Wire control in a

Strona 5 - TABLE 1 – ELECTRICAL RATINGS

11FIG. 5 – REMOTE POTENTIOMETERCONNECTIONFIG. 6 – ANALOG VOLTAGECONNECTIONC. Ground – Be sure to ground (earth) thecontrol by connecting a ground wire

Strona 6

12VII. LOGIC FUNCTIONS AND WIRING.Warning! Do not use any of the logic functions (STP, RTN) as an emergencystop since they are not fail safe. Use on

Strona 7 - IN 240VAC POSITION

13FIG. 10 – STOP COMMANDC. "STOP" (STP) — Usea nor-mally closed(NC) contact betweenterminals "STP" and"RTN." Opening th

Strona 8

1Output voltage provided can vary between 20 and 24VDC14FIG. 11 – JUMPER “JR” OPERATIONJumper "JR" in "F" position (factory settin

Strona 9

15FIG. 14A – ROLLER GEAR UNITFIG. 14B – RIGHT ANGLE UNITFIG. 14C – PARALLEL UNITExample 3: “Cycle on Demand” – Important InformationIn a “Cycle on Dem

Strona 10

16MOMENTARYSTART123456 RUNJOGSTOPRTN+24VCOMLS1 (N/C)TB3SWITCH(N/O)Shield(Do not ground)FIG. 15 – CYCLE ON DEMAND WIRINGThe "Cycle on Demand"

Strona 11

17IX. APPLICATION WIRING DIAGRAMSReversible Model KBPI-240DR (120/240 VAC)Reversing models carry out the same functions as the unidirectional models e

Strona 12

iiTABLE OF CONTENTSSection Pagei. Simplified Setup and Operating Procedures ... 1ii. Safety Warning ...

Strona 13

18X. OPERATION.WARNING! Read Safety Warning on page 2 before attempting to operate thecontrol or severe injury or death can result. Failure to follow

Strona 14

19CAUTION:1. Adjusting the CL above 150% of motor rating can cause overheating anddemagnetization of some PM motors. Consult motor manufacturer.2. Do

Strona 15

20XIII – TROUBLESHOOTING GUIDEMOTOR WILL NOT RUN:1. Check control operation by placing RUN - JOG/STOP in RUN position.2. Make sure disconnect fuses or

Strona 17

XIV – LIMITED WARRANTYFor a period of 18 months from date of original purchase, KB will repair or replace withoutcharge devices which our examination

Strona 18

1i. SIMPLIFIED SETUP AND OPERATING PROCEDURESBefore operating this control you must read these instructions. They are to be used as areference only

Strona 19

2 ii. SAFETY WARNING! — PLEASE READ CAREFULLYThis product should be installed and serviced by a qualified technician, electrician orelectri

Strona 20

3IMPORTANT! Control part number and ratings must correspond to the AC Line voltage, motor voltage and type of operation (Unidirectional or Reversing).

Strona 21

4FIG. 1A CONTROL LAYOUT (Logic Module)

Strona 22 - XIII – TROUBLESHOOTING GUIDE

5FIG. 1B CONTROL LAYOUT (Main Board)JUMPER SHOWNIN 180VDC POSITIONF1T1A2AJ4BA2BJ4AA1AA1BJ2A120V240VIRCLJ1ARM FUSE GNDCOMJOG FWDRUN FWDJOG REVRUN REV+2

Strona 23

6TABLE 2 – GENERAL PERFORMANCE SPECIFICATIONSParameter (Units)SpecificationsModel No. KBPI-240D (P/N 8500)& Model No. KBPI-240DR (P/N 8501)Factory

Strona 24 - KB ELECTRONICS, INC

7TABLE 3 – SELECTABLE JUMPER REFERENCE CHARTJumper Location* Description Factory SettingJ1 1Establishes the range of maximumarmature current.See sec.